USAfixTM - Repair Guide (RG) - Master Email RG
- Check wiring between terminal block and curve support
 Level of Difficulty - HIGH  Estimated Completion Time - 20 minutes
TASKI - Jet 38

Tools Required
Tool 
Screwdriver-phillips
Volt meter (True RMS capable)

Parts Required


Step Procedure & Parts & Tools
1 REMOVE THE POWER CORD FROM THE CORD HOOK.

2 UNHOOK THE VAC HOSE FROM THE HOSE HOOK.

3 SLIDE UP ON THE BAG COVER LATCH. PULL THE BAG COVER FROM THE MACHINE.

4 PUSH IN ON THE RED LEVER ON THE RIGHT SIDE TO UNLOCK THE BAG.

5 PULL THE BAG DOWN OFF THE INTAKE HOSE.

6 REMOVE THE 4 SCREWS HOLDING THE UPPER VAC HOUSING.
Screwdriver-phillips

7 PULL THE UPPER VAC HOUSING UP TO SEPARATE IT FROM THE LOWER VAC HOUSING.

8 LOOSEN THE 2 SCREWS HOLDING THE GUIDE HOUSING.
Screwdriver-phillips

9 PULL UP ON THE TOP OF THE UPPER VAC HOUSING TO SEPARATE IT FROM THE LOWER VAC HOUSING.

10 LOCATE THE TERMINAL BLOCK ON THE BOTTOM OF THE MIDDLE VAC HOUSING. INSERT 1 LEAD IN THE TERMINAL BLOCK AND 1 LEAD ON THE CURVE SUPPORT. THE CURVE SUPPORT IS LOCATED ON THE BOTTOM OF THE LOWER VAC HOUSING. SET THE VOLT METER TO CONTINUITY. IF THE VOLT METER BEEPS, THE WIRING IS OKAY. REPEAT THIS STEP FOR THE REMAINING WIRES IN THE TERMINAL BLOCK. (GREEN/YELLOW AND 2 BLUE WIRES).
Volt meter (True RMS capable)